Skip to main content

Used Industrial Generators & Gas Generator Sets for Sale


2 results

Get alerts about new generator listings by email

Looking for Something Specific?

Most of our inventory sells before we can list it online. If you need a specific brand, model, or specification, tell us what you need—we have access to unlisted equipment and machines coming in from plant closures.

Browse Used Industrial Generators by Brand

Browse Used Industrial Generators by Country

Looking to Sell Your Industrial Generators?

Meadoworks is an active cash buyer of used industrial equipment. Get a free valuation from our AMEA-certified appraisers.

Sell Your Equipment

About Used Industrial Generators

Industrial generators provide prime and standby power for manufacturing plants, where an outage means scrapped material, damaged tooling or halted production. Used generator sets (gensets) come as natural gas units (suited to continuous duty, with no fuel storage), diesel units (the usual choice for standby power) and portable or towable sets. The specifications that matter are kW rating, voltage (480V three-phase for most plants), running hours, and transfer switch and paralleling controls.

Standby sets often have very low hours for their age. Ask for the hour meter, maintenance and oil-analysis records and any load-bank test results, and confirm emissions requirements for your site before buying.

Generators currently listed include GE Jenbacher natural gas generator packages and a Caterpillar SR4B generator end. Looking for electrical transformers instead? See our used transformers page. Request a quote on any listing or call us at 800-323-0307 for current availability.

How to Choose a Used Industrial Generator

Standby or prime power

A standby generator runs only when the utility fails and often has very few hours. A prime or continuous-duty set runs for long periods to carry the plant or cut peak power costs, which favors natural gas units with no fuel to store.

Size on the load you must carry — molding machines, chillers, compressors and lighting — and on starting current for large motors, not only on running load.

Fuel, voltage and switching

Diesel is the usual standby choice; natural gas suits long running and sites with a gas supply. Most plants need 480V three-phase.

The transfer switch and any paralleling controls decide how the set connects to your plant. Ask whether they come with the generator, and check emissions rules for your site before buying.

Industrial Generator Specs to Compare

Output (kW)

Typical range: About 50 kW to 2 MW

Size on your critical load and the starting current of large motors.

Fuel

Diesel for standby, natural gas for long running.

Voltage and phase

Typical range: Usually 480V three-phase

Has to match your plant distribution.

Running hours

Standby sets often have low hours; read them with the maintenance records.

Rating and emissions tier

Standby vs prime rating, and whether the engine meets the emissions rules where you run it.

What to Inspect on a Used Industrial Generator

  • Ask for a load-bank test

    A test at load shows the set holds voltage and frequency; idle runs hide problems.

  • Read maintenance and oil analysis

    Hours, oil changes, coolant and any overhaul history.

  • Check the generator end

    Insulation test results and the condition of the windings and connections.

  • Confirm the controls and switch

    Control panel model, transfer switch and paralleling gear, and whether they are included.

  • Check emissions and permits

    Confirm what your state or local air rules require for the engine tier and hours.

Related Equipment

Common Applications

Plant prime power
Plant standby power
Combined heat & power
Peak shaving
Process protection

Frequently Asked Questions

How much does a used industrial generator cost?

Typical used-market ranges scale with kW: 50–150 kW standby diesel sets about $8,000–$25,000, 250–500 kW sets about $20,000–$60,000, and 750 kW–2 MW units about $50,000–$200,000+. Low-hour standby units bring more. Hours, brand, emissions tier and an included transfer switch move the price. These are typical ranges, not a quote on any listing — contact Meadoworks at 800-323-0307.

What should I check on a used industrial generator?

Check the running hours, maintenance and oil-analysis records, and any load-bank test results. Confirm the kW rating, voltage and frequency match your plant, ask whether controls, switchgear and a transfer switch are included, and check emissions requirements for your location.

Natural gas vs diesel generator — which is better for a plant?

Natural gas generators suit continuous or prime power because they run on a utility gas line with no fuel storage. Diesel generators are the usual choice for emergency standby because they start and take load quickly and keep running from on-site fuel when utilities are down.

What size generator does a manufacturing plant need?

Add the load you must keep running — presses, chillers, compressors, controls and lighting — and allow for the starting current of the largest motors. Many plants back up only critical loads rather than the whole plant.

Standby vs prime rating — what's the difference?

A standby rating is for emergency use when the utility fails. A prime rating is for running for long periods at a varying load. Running a standby-rated set as prime power shortens its life.

What should come with a used generator?

Ask whether the control panel, transfer switch, enclosure, fuel tank or gas train, and any paralleling gear are included — they can be a large part of the cost of a complete system.

Need Help Finding the Right Equipment?

Contact our team with your specifications and we'll help you find the right machine.