Skip to main content

Used Water Treatment Systems for Sale


Recently sold

Get alerts about new plant support listings by email

Looking for Something Specific?

Most of our inventory sells before we can list it online. If you need a specific brand, model, or specification, tell us what you need—we have access to unlisted equipment and machines coming in from plant closures.

Looking to Sell?

Meadoworks is an active cash buyer of used industrial equipment. Get a free valuation from our AMEA-certified appraisers.

Sell Your Equipment

About Used Water Treatment Systems

Every press, extruder and chiller in a plastics plant depends on water that is the right temperature, the right pressure and clean enough not to scale or plug a mold. A water treatment system is the equipment that keeps it that way. In a plant, the term covers pump and tank stations that circulate tower or chilled water, filtration that takes out solids, softeners and reverse osmosis units that remove hardness and dissolved minerals, and chemical feed that controls corrosion and biological growth.

Pump and tank systems are the most common piece. A cold well and a hot well, each with its own pumps, separate the water going out to the process from the water coming back to the cooling tower or chiller. Integrated stations such as the Frigel Aquagel pump station package the tanks, pumps and controls on one frame. Filtration ranges from bag and cartridge filters at a single machine to sand and media filters on the whole loop.

Softening and reverse osmosis matter most where water runs through small passages: mold cooling channels, hot runner manifolds and laser or welding chillers. Hard water leaves scale that narrows those channels and slows the cycle. Deionized or RO water is often specified for closed loops on newer temperature controllers and chillers.

Buying a used water treatment system starts with flow and pressure. Add up the gallons per minute your presses, mold controllers and chillers draw, and the pressure each needs at the far end of the header. Then decide what has to come out of the water, based on a test of your supply. Tank material, pump seals and the control panel are the common wear items.

Meadoworks sells this equipment from molding and extrusion plant closures, where it often comes with the chillers and towers it served. The Frigel pump station we have listed is a 2018 Aquagel unit, and plant closures regularly include tanks, pumps and filtration skids. Ask for the pump curves and the last service records, and plan the rigging with the chiller or tower so the loop goes in together.

How to Choose a Used Water Treatment System

Size the Loop Before You Pick the Equipment

Add up the flow every machine on the loop needs at full load, then add margin for growth. Size the pumps for that flow at the pressure the farthest machine needs. A pump station that is too small starves the last press on the header; one far too large wastes power and fights its own valves.

Then test the supply water. Hardness, dissolved solids and suspended solids decide whether you need filtration alone, a softener, or reverse osmosis for a closed loop.

By Class: Used Price Ranges

Bag and cartridge filter housings and small softeners: about $500–$5,000.

Pump and tank stations (cold well and hot well with pumps): about $5,000–$40,000 by flow and tank size.

Reverse osmosis and deionizing systems: about $5,000–$30,000+.

What moves the price: flow and tank size, stainless versus poly tanks, pump condition, controls, and whether the filters and chemical feed come with it. These are typical used-market ranges, not a quote on any one system. For a current price, request a quote or call 800-323-0307.

Water Treatment System Specs to Compare

Flow (GPM)

Has to cover every press, controller and chiller on the loop.

Pump pressure

Enough head to reach the farthest machine on the header.

Tank size and material

Stainless lasts longer; poly tanks are lighter and cheaper.

Filtration

Bag, cartridge, sand or media, by the solids in your water.

Treatment type

Softener for hardness, reverse osmosis for dissolved minerals.

Voltage

Typical range: Usually 460V three-phase on pump stations

Match it to your plant service before you buy.

What to Inspect on a Used Water Treatment System

  • Run the pumps

    Listen for bearing noise and check the seals for leaks.

  • Inspect the tanks

    Look for cracks, corrosion and scale inside the cold and hot wells.

  • Check the controls

    Level switches, pump alternation and alarms should all work.

  • Look at the filters

    Housings, gauges and the media or membranes, and when they were last changed.

  • Ask for the pump curves

    So you can match the station to your flow and pressure.

  • Confirm what is included

    Valves, piping, chemical feed and any chiller or tower it served.

Related Equipment

Water Treatment Systems Brands We've Sold

Common Applications

Cooling tower water loops
Chilled water for molds
Closed-loop process cooling
Hard water softening
Reverse osmosis for hot runners
Filtration for extrusion cooling tanks

Frequently Asked Questions

What does a water treatment system do in a plastics plant?

It keeps process and cooling water at the flow, pressure and cleanliness the machines need. That includes pump and tank stations that circulate tower or chilled water, filters that remove solids, softeners and reverse osmosis units that take out hardness and minerals, and chemical feed that limits corrosion and growth. Clean water keeps mold cooling channels open and cycle times steady, and it protects chillers, temperature controllers and hot runners from scale.

Why do molders use a cold well and a hot well?

The two tanks keep the water going out to the process separate from the water coming back. Pumps draw cold water from the cold well and send it to the presses and controllers. The warmer return water goes to the hot well, and a second set of pumps sends it to the cooling tower or chiller, which returns it cool to the cold well. Keeping the two apart holds the supply temperature steady when the plant load changes.

Do I need reverse osmosis water for mold cooling?

Not always. Open tower loops usually run treated city or well water with filtration and chemical control. Closed loops on newer chillers, temperature controllers and hot runner systems often call for softened, deionized or reverse osmosis water, because minerals scale small passages and heater surfaces. Test your supply water and check the requirements in the manuals for the machines on the loop before you decide what to buy.

How do I size a used pump and tank station?

Total the gallons per minute every machine on the loop draws at full load, add margin, and choose pumps that deliver that flow at the pressure your farthest machine needs. Then size the tanks so the pumps have enough water to draw without running dry when the load swings. Ask for the pump models and curves on any used station and compare them with your header length and piping before you buy.

What wears out on a used water treatment system?

Pump seals and bearings, filter media and membranes, level switches, and valves are the usual wear items. Poly tanks can crack and steel tanks can corrode, and scale builds up inside tanks and piping on hard water. None of these are usually expensive alone, but they add up. Run the pumps, open the tanks if you can, and ask when the filters, membranes or resin were last changed.