Skip to main content

Used Water Temperature Controllers for Sale

All used thermolators & mold temperature controllers (29) →


See all 29 Thermolators & Temperature Controllers →

25 results

Used 2024 HB-Therm HB-100Z61 Water Temperature Controllers

Lot 21 · Item #6920

2024 HB-Therm Thermo-5 Water Temperature Control Unit

East Dundee, IL

Current bid$230

Ends Mon, Nov 30, 10:40 AM CT · 6 bids

Place bid
Used 2024 HB-Therm HB-160Z61 Water Temperature Controllers

Lot 14 · Item #6913

2024 HB-Therm Thermo-5 Water Temperature Control Unit

East Dundee, IL

Current bid$1,250

Ends Mon, Nov 30, 10:26 AM CT · 28 bids

Place bid
Used 2023 Frigel RBM80/12 SPS Water Temperature Controllers

Lot 11 · Item #6910

2023 Frigel Turbogel Flow Booster Temperature Controller

East Dundee, IL

Current bid$350

Ends Mon, Nov 30, 10:20 AM CT · 21 bids

Place bid
Used 2022 HB-Therm HB-160Z1 Water Temperature Controllers

Lot 16 · Item #6915

2022 HB-Therm Thermo-5 Water Temperature Control Unit

East Dundee, IL

Current bid$600

Ends Mon, Nov 30, 10:30 AM CT · 20 bids

Place bid
Used 2022 HB-Therm HB-160Z1 Water Temperature Controllers

Lot 15 · Item #6914

2022 HB-Therm Thermo-5 Water Temperature Control Unit

East Dundee, IL

Current bid$500

Ends Mon, Nov 30, 10:28 AM CT · 16 bids

Place bid
Used 2021 HB-Therm HB-160Z1 Water Temperature Controllers

Lot 17 · Item #6916

2021 HB-Therm Thermo-5 Water Temperature Control Unit

East Dundee, IL

Current bid$350

Ends Mon, Nov 30, 10:32 AM CT · 20 bids

Place bid
Used 2020 Advantage SK-1035G Water Temperature Controllers

Lot 6 · Item #6956

2020 Advantage SK-1035G Temp Controller

USA · Register to see location

Current bid$100

Ends Thu, Dec 10, 10:10 AM CT · 1 bid

Place bid
Used 2020 Matsui MC5-G1-88L95 Water Temperature Controllers

Lot 8 · Item #6946

2020 Matsui MC5-G1 Temperature Controller

Gilberts, IL

Current bid$275

Ends Wed, Dec 2, 10:14 AM CT · 17 bids

Place bid
Used 2020 HB-Therm HB-160Z2 Water Temperature Controllers

Lot 19 · Item #6918

2020 HB-Therm Thermo-5 Water Temperature Control Unit

East Dundee, IL

Current bid$450

Ends Mon, Nov 30, 10:36 AM CT · 25 bids

Place bid
Used 2020 Frigel RCD80/12SP Digital Water Temperature Controllers

Lot 10 · Item #6909

2020 Frigel Turbogel Flow Booster Temperature Controller

East Dundee, IL

Current bid$775

Ends Mon, Nov 30, 10:18 AM CT · 14 bids

Place bid
Used 2020 Frigel RBD210/24 HP Water Temperature Controllers

Lot 9 · Item #6908

2020 Frigel Turbogel Flow Booster Temperature Controller

East Dundee, IL

Current bid$130

Ends Mon, Nov 30, 10:16 AM CT · 4 bids

Place bid
Used 2019 HB-Therm HB-100Z1 Water Temperature Controllers

Lot 24 · Item #6923

2019 HB-Therm Thermo-5 Water Temperature Control Unit

East Dundee, IL

Current bid$450

Ends Mon, Nov 30, 10:46 AM CT · 24 bids

Place bid
Used 2019 HB-Therm HB-100Z2 Water Temperature Controllers

Lot 23 · Item #6922

2019 HB-Therm Thermo-5 Water Temperature Control Unit

East Dundee, IL

Current bid$100

Ends Mon, Nov 30, 10:44 AM CT · 1 bid

Place bid
Used 2019 HB-Therm HB-100Z1 Water Temperature Controllers

Lot 22 · Item #6921

2019 HB-Therm Thermo-5 Water Temperature Control Unit

East Dundee, IL

Current bid$350

Ends Mon, Nov 30, 10:42 AM CT · 12 bids

Place bid
Used 2019 HB-Therm HB-VS180-US2 (Vario) Water Temperature Controllers

Lot 13 · Item #6912

2019 HB-Therm Thermo-5 Vario Water Temperature Control Unit

East Dundee, IL

Current bid$100

Ends Mon, Nov 30, 10:24 AM CT · 1 bid

Place bid
Used 2018 Matsui MC5-G1-88L95 Water Temperature Controllers

Lot 10 · Item #6948

2018 Matsui MC5-G1 Temperature Controller

Gilberts, IL

Current bid$275

Ends Wed, Dec 2, 10:18 AM CT · 17 bids

Place bid
Used 2018 HB-Therm HB-140Z1 Water Temperature Controllers

Lot 20 · Item #6919

2018 HB-Therm Thermo-5 Water Temperature Control Unit

East Dundee, IL

Current bid$300

Ends Mon, Nov 30, 10:38 AM CT · 12 bids

Place bid
Used 2017 Frigel RBD210/24 HP Water Temperature Controllers

Lot 8 · Item #6907

2017 Frigel Turbogel Flow Booster Temperature Controller

East Dundee, IL

Current bid$130

Ends Mon, Nov 30, 10:14 AM CT · 4 bids

Place bid
Used 2016 Matsui MC5-G1-88L95 Water Temperature Controllers

Lot 9 · Item #6947

2016 Matsui MC5-G1 Temperature Controller

Gilberts, IL

Current bid$275

Ends Wed, Dec 2, 10:16 AM CT · 17 bids

Place bid
Used 2016 Frigel RBD40/12SP Water Temperature Controllers

Lot 12 · Item #6911

2016 Frigel Turbogel Flow Booster Temperature Controller

East Dundee, IL

Current bid$100

Ends Mon, Nov 30, 10:22 AM CT · 1 bid

Place bid
Used 2013 Temptek VT-275-LX Water Temperature Controllers

Lot 5 · Item #6955

2013 Temptek VT-275-LX Temp Controller

USA · Register to see location

Current bid$100

Ends Thu, Dec 10, 10:08 AM CT · 1 bid

Place bid
Used 2013 Temptek VT-275-LX Water Temperature Controllers

Lot 4 · Item #6954

2013 Temptek VT-275-LX Temp Controller

USA · Register to see location

Current bid$100

Ends Thu, Dec 10, 10:06 AM CT · 1 bid

Place bid
Used Comet Plastic Equipment STM Water Temperature Controllers

Lot 3 · Item #7113

Comet STM Mold Temperature Controller

USA · Register to see location

Starting bid$100

Ends Wed, Dec 16, 10:04 AM CT

Place bid
Used Conair THDABHCMA00A Water Temperature Controllers

Lot 4 · Item #6897

Lot of (2) Conair Thermolators

USA · Register to see location

Starting bid$100

Taking offers · bidding opens Tue, Dec 1, 10:00 AM CT

Make an offer

Water Temperature Controllers by the numbers

From our own catalog: machines listed now and machines we have sold. Updated every few minutes.

Our track record

324 machines sold · 23 makes · model years 1993–2023 · 77 sold at our own auctions

By brand

BrandIn stock nowSold by MeadoworksModel years
HB-Therm12112018–2024
Frigel502016–2023
Matsui3241997–2020
Wittmann2112004–2023
Temptek232001–2013
Conair1821995–2005
Advantage Engineering1361996–2022
Delta T14—
Budzar132008
Comet Plastic Equipment10—
Get alerts about new auxiliary equipment listings by email

Looking for Something Specific?

Most of our inventory sells before we can list it online. If you need a specific brand, model, or specification, tell us what you need—we have access to unlisted equipment and machines coming in from plant closures.

Looking to Sell?

Meadoworks is an active cash buyer of used industrial equipment. Get a free valuation from our AMEA-certified appraisers.

Sell Your Equipment

About Used Water Temperature Controllers

A water temperature controller, called a water thermolator on most plant floors, circulates water through a mold, die, roll or platen and holds it at a setpoint. The cabinet holds a pump, an electric heater, a cooling valve and a probe. Water leaves the unit, picks up or gives off heat in the tool, and comes back. The controller then adds heat or opens cooling until the return matches the number on the display. That closed loop is the whole job. It is not a chiller, and it is not a hose teed off the tower. If you have not decided between water and hot oil, start with the broader thermolator group. The notes below cover water only.

Water units and oil units solve different temperature bands. A water thermolator is the everyday choice up to about 250 F, which covers most commodity resins and a lot of engineering work. A single-zone cabinet feeds one circuit, often one mold half. A dual-zone cabinet runs two temperatures from one frame, which matters when the cavity and the core are supposed to run apart. Direct-injection cooling mixes tower or chiller water into the process loop, so it cools fast and it also imports whatever is in the plant water. Indirect cooling keeps a heat exchanger between the two loops, so rust and treatment chemicals stay out of the mold. Pressurized water circuits can sit closer to boiling without a cloud of steam. When the tool needs to run hotter than water can comfortably hold, the right machine is a hot oil unit, not a larger water heater.

On a molding cell the water temperature controller sits on the floor beside the press, between the chilled-water supply and the mold hoses. The chiller or cooling tower is what removes heat from the building. The controller decides how warm the steel is, and that temperature is often well above the chilled water. Dryers, vacuum loaders and blenders feed the screw. Size the water unit together with the portable chiller that feeds it, and keep hot oil units in mind for the tools that outgrow water. Blow molds and extrusion dies use the same idea: stable metal temperature, short hoses, and a pump that can push through the passages that were actually drilled in the tool.

Heater kilowatts, pump horsepower and supply voltage decide whether a used water temperature controller can run your tool. A 9 kW heater on 460 volts, three phase, is a common press-side package in North American plants. A 230 volt cabinet will not land on a 460 volt cell without a transformer. Nameplate horsepower is not the same as flow through a restricted waterline. Ask what gallons per minute the pump delivers at the pressure your mold actually needs. Hoses, shaft seals and a scaled exchanger are the parts people replace. The cabinet and the pump housing usually outlast them.

Meadoworks offers these water units when they come off molding cells in plant closures, from consignments, and from auctions where a press is sold with the auxiliary that ran beside it. Confirm heater size, pump, voltage and that the circuit is water before you compare two cabinets. Buyers can inspect before they commit, and when a whole cell moves we coordinate rigging and the truck with the rest of the machines instead of treating the cabinet as a loose box.

How to Choose a Used Water Temperature Controller

How to Size a Water Thermolator

Start from the mold, not from the press tonnage. The heater has to bring the steel up to setpoint in a reasonable time and then hold it while the resin keeps arriving with heat. A small tool and a slow cycle can live on a 6 or 9 kW heater. A large mold, a high melt temperature or a short cycle needs more kilowatts, and two mold halves at two setpoints need two zones or two cabinets. Pump flow has to match the waterlines. A high-horsepower pump on a mold with tiny passages only makes pressure and heat. A weak pump on a large tool never reaches the far cavities.

Voltage and phase have to match the cell. Most US plants feed these cabinets with 460 volts, three phase. Confirm the cooling source too. The unit needs a supply of water colder than the setpoint, from a chiller or a tower, and a return path that is not kinked under the press. Leave hose length short. Every extra foot is heat loss and pressure drop.

Direct Injection vs Indirect Cooling

Direct injection is the simpler circuit. When the mold is too hot, a valve lets cold plant water into the loop and dumps the overflow. Response is quick, and the cabinet is easier to service. The cost is that tower water, treatment chemicals and rust travel through the mold. Indirect units put a heat exchanger between the plant water and the water that touches the tool. The process loop stays cleaner, which matters on molds with small passages and on tools that sit idle between runs.

If your tower water is dirty or your molds are expensive to clean, take the exchanger. If the plant water is clean and you want the fastest pull-down, direct injection is the usual choice. Neither design replaces a chiller. Both of them borrow cold water from somewhere else.

By size: Typical Used Water Temperature Controller Price Ranges

Single-zone units, about 6–9 kW: $1,000–$3,000

Larger units, about 12–24 kW: $2,500–$5,000

Dual-zone units: $3,500–$8,000

What moves the price — heater kW, pump size, direct or indirect cooling, zones, controller generation and age. A unit that heats and cools on a test stand brings more.

These are typical used-market ranges, not a quote on any machine. For a current figure on a specific machine, request a quote or call 800-323-0307.

Water Temperature Controller Specs to Compare

Heater size (kW)

Typical range: 6–12 kW on press-side units

Sets how fast the mold reaches setpoint and whether the unit can hold temperature on a hot cycle.

Pump flow and pressure

Typical range: About 20–50 gpm on small units

Flow at real back-pressure matters more than the horsepower printed on the motor plate.

Maximum water temperature (F)

Typical range: Up to about 250 F

Water units cover most molds. Tools that must run hotter belong on a hot oil unit.

Supply voltage

Typical range: 230 or 460 V, 3 phase

A voltage mismatch needs a transformer or a different cabinet before the unit can run.

Number of zones

Typical range: 1 or 2

Two zones let the cavity and the core hold different setpoints from one shared frame.

Cooling connection (in)

Typical range: 3/4 to 1-1/2 in

Hose and valve size limit how fast the unit can pull mold temperature back down.

What to Inspect on a Used Water Temperature Controller

  • Run the heater to setpoint

    Confirm the display climbs and the contactor pulls in. A heater that never leaves room temperature is an element or a contactor, not a calibration issue.

  • Listen to the pump

    A growl, a leak at the shaft seal, or a pump that will not prime means a rebuild before the unit can hold flow through a mold.

  • Open the cooling valve

    With cold supply water connected, the temperature should fall. A stuck valve or a packed strainer leaves the mold hot.

  • Inspect the heat exchanger

    Scale and sludge on an indirect unit cut cooling capacity. A plugged exchanger looks fine until the mold will not come down.

  • Read the nameplate voltage

    Match volts, phase and full-load amps to the cell. A 230 volt cabinet on a 460 volt bus is not a hose change.

  • Check hoses and quick connects

    Cracked hoses and leaking couplers dump water into the press. They are cheap, and they are the usual reason a unit looks neglected.

  • Look for a leaky-mold mode

    Some cabinets can isolate a cracked mold and keep running. If you need that feature, confirm the valve is actually there.

  • Cycle the controller

    Change the setpoint up and down. A dead display, a probe that reads open, or a unit that hunts will not hold a mold.

Related Equipment

Common Applications

Injection mold temperature control
Blow mold conditioning
Extrusion die temperature
Roll and calendar temperature
Hot-runner manifold support
Rubber and elastomer molds
Thermoform tool heating
Platen and die heating

Frequently Asked Questions

What temperature is too high for a water temperature controller?

A water temperature controller pumps water through the mold and holds a setpoint, usually no higher than about 250 F. Above that, the loop wants pressure to stay liquid, or it wants oil instead. Polyethylene, polypropylene and a lot of ABS and nylon work sit comfortably on water. If the resin sheet calls for a mold well above that band, the right machine is a hot oil unit. Staying on water and turning the setpoint past the nameplate trips safeties or boils the circuit.

How do I size a water temperature controller?

Match heater kilowatts to the mold and the cycle, not to the press tonnage. Small tools often run on 6 to 9 kW. Large molds and hot resins need more, and two setpoints need two zones. Then match the pump to the waterlines. You need flow at the pressure those passages actually create, not just a horsepower number. Finally match the cabinet voltage to the cell, usually 460 volts, three phase, in a US plant. The cooling supply has to be colder than the setpoint.

Direct injection or indirect cooling on a water unit?

Direct injection lets cold plant water into the process loop when the mold is too hot. It responds quickly and the cabinet is simpler. It also sends tower rust and treatment chemicals through the mold. Indirect cooling puts a heat exchanger between the two loops, so the water that touches the tool stays cleaner. Pick direct injection when the plant water is clean and you want the fastest pull-down. Pick the exchanger when the tower is dirty or the waterlines are small and expensive to descale. Neither choice replaces a chiller. Both of them borrow cold water from one.

What should I check on a used water temperature controller?

Run it. The heater should reach setpoint, the pump should be quiet and hold pressure, and the cooling valve should pull the temperature back down when cold water is connected. Read the nameplate for voltage and kilowatts. Look at the shaft seal, the hoses and, on an indirect unit, the exchanger for scale. A dead probe or a stuck contactor is a repair. A cabinet full of water is a different problem. Ask which fluid it was built for so you do not put oil in a water unit.

Do I still need a chiller with a water temperature controller?

Yes. The thermolator moves heat around the mold. It does not throw that heat out of the building. Cooling comes from a portable chiller, a central chiller or a tower, and the temperature controller only borrows that cold water when the mold is above setpoint. A cell with controllers and no chiller will climb until the molds run hot. Size the chiller for the presses and the other loads, then put a controller on each tool that needs its own setpoint.

What does an Advantage thermolator nameplate tell me?

Read heater kilowatts, pump horsepower, voltage, phase and maximum fluid temperature before you compare it with another brand. Those five numbers tell you whether the cabinet fits the mold and the electrical panel. The series name matters less than whether it is a water circuit or an oil circuit and whether cooling is direct or through an exchanger. Sterlco, Conair, Matsui, AEC and Mokon publish the same facts on their plates. Match the plate to the tool, then compare condition.